Frost depth sets the floor
Footings must bear below the local frost line so seasonal ice doesn't lift the deck. That depth ranges from 12 inches in the South to 48 inches or more in northern states — your jurisdiction publishes the number.
Soil bearing and footing size
Depth keeps the footing from heaving; width keeps it from sinking. We size each footing from the tributary load it carries and the assumed soil bearing capacity, which is why a large deck may have footings of different sizes.
The ledger connection
Most deck failures happen where the deck meets the house. Inspectors look for through-bolts or structural screws at the code-prescribed spacing, proper flashing, and solid rim joist behind the ledger. Our deck packages detail all three so the inspection is a formality.